The Evaluation and Comparison of Removable Dentures Constructed with The SR-IVOCAP System and The Traditional System.
Life Sciences -Dentistry
DOI:
https://doi.org/10.22376/ijlpr.2023.13.5.L302-L310Keywords:
SR IVOCAP Dentures, Compression, Molding, Injection, Patient Satisfaction.Abstract
The treatment of edentulous patients is still a challenging problem. Acrylic resin is the most used material forconstructing removable denture bases. The main disadvantage of this material is resin shrinkage, which occurs during and afterpolymerization. Our study aimed to evaluate the denture parameters regarding patient satisfaction regarding the removabledentures constructed with two different processing techniques: compression molding and injection. 80 patients, who came in theUniversity Dental Clinic, Tirana were examined and evaluated. Those who fulfilled the criteria were treated with removabledentures. The patients were divided into two groups: in the first group, 40 patients were treated with removable denturesconstructed with the compression molding technique, and in the second group, 40 patients were treated with removable denturesconstructed with the injection molding technique. All the clinical and laboratory procedures until the processing technique wereidentical. After denture delivery, all the patients were re-scheduled to fulfill a questionnaire regarding four parameters of theremovable dentures: denture stability, mastication efficiency, denture comfort, and quality of dentures in general. Results. Thedescriptive statistics of the data were done. Sample t-test showed that the SR IVOCAP dentures had higher mean values for allthe parameters than the traditional dentures. Based on our study, the satisfaction of the patients treated with removable dentureswith the SR-IVOCAP system for all the parameters evaluated was higher compared to the patient satisfaction treated withtraditional removable dentures.
References
Kawara M, Komiyama O, Kimoto S, Kobayashi N, Kobayashi K, Nemoto K. Distortion behavior of heat-activated acrylic denture-base resin in conventional, long, low-temperature processing methods. J Dent Res. 1998 Jun;77(6):1446-53. Doi: 10.1177/00220345980770060901. PMID: 9649173.
Parvizi A, Lindquist T, Schneider R, Williamson D, Boyer D, Dawson DV. Comparison of the dimensional accuracy of injection-molded denture base materials to conventional pressure-pack acrylic resin. J Prosthodont. 2004 Jun;13(2):83-9. Doi: 10.1111/j.1532-849X.2004.04014.x. PMID: 15210003.
Darvell BW, Clark RK. The physical mechanisms of complete denture retention. Br Dent J. 2000 Sep 9;189(5):248-52. Doi: 10.1038/sj.bdj.4800734. PMID: 11048392.
Jacob RF. The traditional therapeutic paradigm: complete denture therapy. J Prosthet Dent. 1998 Jan;79(1):6-13. Doi: 10.1016/s0022-3913(98)70186-6. PMID: 9474534.
Jacobson TE, Krol AJ. A contemporary review of the factors involved in complete denture retention, stability, and support. Part I: retention. J Prosthet Dent. 1983 Jan;49(1):5-15. Doi: 10.1016/0022-3913(83)90228-7. PMID: 6337253.
Li D, Yang ST, Yuan Q, Mo AC, Yue L. [Accuracy and retention of denture bases fabricated by injection molding, milling, and three-dimensional printing]. Zhonghua Kou Qiang Yi Xue Za Zhi. 2022 Sep 9;57(9):927-931. Chinese. Doi: 10.3760/cma.j.cn112144-20220126-00032. PMID: 36097939.
Pryor, Walter J. “Injection Molding of Plastics for Dentures.” Journal of the American Dental Association 29 (1942): 1400-1408.
Anderson GC, Schulte JK, Arnold TG. Dimensional stability of injection and conventional processing of denture base acrylic resin. J Prosthet Dent. 1988 Sep;60(3):394-8. Doi: 10.1016/0022-3913(88)90292-2. PMID: 3050054.
Woelfel Jb, Paffenbarger Gc, Sweeney Wt. Dimensional changes occurring in dentures during processing. J Am Dent Assoc. 1960 Oct;61:413-30. Doi: 10.14219/jada.archive.1960.0205. PMID: 13786165.
Moslehifard E, Ghaffari T, Abolghasemi H, Maleki Dizaj S. Comparison of Conventional Pressure-packed and Injection Molding Processing Methods for an Acrylic Resin Denture based on Microhardness, Surface Roughness, and Water Sorption. Int J Dent. 2022 Aug 17;2022:7069507. Doi: 10.1155/2022/7069507. PMID: 36034479; PMCID: PMC9402357.
Goodkind RJ, Schulte RC. Dimensional accuracy of pour acrylic resin and conventional processing of cold-curing acrylic resin bases. J Prosthet Dent. 1970 Dec;24(6):662-8. Doi: 10.1016/0022-3913(70)90103-4. PMID: 5273665.
Takamata T, Setcos JC. Resin denture bases: review of accuracy and methods of polymerization. Int J Prosthodont. 1989 Nov-Dec;2(6):555-62. PMID: 2701070.
Sykora O, Sutow EJ. Posterior palatal seal adaptation: influence of processing technique, palate shape and immersion. J Oral Rehabil. 1993 Jan;20(1):19-31. Doi: 10.1111/j.1365-2842.1993.tb01511.x. PMID: 8429420.
Yunus N, Rashid AA, Azmi LL, Abu-Hassan MI. Some flexural properties of a nylon denture base polymer. J Oral Rehabil. 2005 Jan;32(1):65-71. Doi: 10.1111/j.1365-2842.2004.01370.x. PMID: 15634304.
Gharechahi J, Asadzadeh N, Shahabian F, Gharechahi M. Dimensional changes of acrylic resin denture bases: conventional versus injection-molding technique. J Dent (Tehran). 2014 Jul;11(4):398-405. Epub 2014 Jul 31. PMID: 25584050; PMCID: PMC4283740.
Jackson AD, Grisius RJ, Fenster RK, Lang BR. Dimensional accuracy of two denture base processing methods. Int J Prosthodont 1989; 2:421-8.
Nogueira TE, Dias DR, Leles CR. Mandibular complete denture versus single-implant overdenture: a systematic review of patient-reported outcomes. J Oral Rehabil. 2017 Dec;44(12):1004-1016. Doi: 10.1111/joor.12550. Epub 2017 Sep 4. PMID: 28805255.
Abby A, Kumar R, Shibu J, Chakravarthy R. Comparison of the linear dimensional accuracy of denture bases cured the by conventional method and by the new press technique. Indian J Dent Res. 2011 Mar-Apr;22(2):200-4. Doi: 10.4103/0970-9290.84282. PMID: 21891885.
Venus H, Boening K, Peroz I. The effect of processing methods and acrylic resins on the accuracy of maxillary dentures and toothless denture bases: an in vitro study. Quintessence Int. 2011 Sep;42(8):669-77. PMID: 21842007.
Baydas S, Bayindir F, Akyil MS. Effect of processing variables (different compression packing processes and investment material types) and time on the dimensional accuracy of polymethyl methacrylate denture bases. Dent Mater J. 2003 Jun;22(2):206-13. Doi: 10.4012/dmj.22.206. PMID: 12873123.
Salim S, Sadamori S, Hamada T. The dimensional accuracy of rectangular acrylic resin specimens cured by three denture base processing methods. J Prosthet Dent. 1992 Jun;67(6):879-81. Doi: 10.1016/0022-3913(92)90606-b. PMID: 1403883.21.
El Bahra S, Ludwig K, Samran A, Freitag-Wolf S, Kern M. Linear and volumetric dimensional changes of injection-molded PMMA denture base resins. Dent Mater. 2013 Nov;29(11):1091-7. doi: 10.1016/j.dental.2013.07.020. Epub 2013 Sep 1. PMID: 24001949.
Keenan PL, Radford DR, Clark RK. Dimensional change in complete dentures fabricated by injection molding and microwave processing. J Prosthet Dent. 2003 Jan;89(1):37-44. doi: 10.1067/mpr.2003.3. PMID: 12589284.
Woelfel Jb, Paffenbarger Gc, Sweeney Wt. Clinical Evaluation of Complete Dentures Made Of 11 Different Types Of Denture Base Materials. J Am Dent Assoc. 1965 May; 70:1170-88. Doi: 10.14219/Jada.Archive.1965.0208. Pmid: 14284642.
DaBreo EL, Herman P. A new method of measuring dimensional change. J Prosthet Dent. 1991 May;65(5):718-22. doi: 10.1016/0022-3913(91)90212-f. PMID: 2051398.
Mazaro JV, Gennari Filho H, Vedovatto E, Amoroso AP, Pellizzer EP, Zavanelli AC. Influence of different base thicknesses on maxillary complete denture processing: linear and angular graphic analysis on the movement of artificial teeth. J Craniofac Surg. 2011 Sep;22(5):1661-5. doi: 10.1097/ SCS.0b013e31822e5d8c. PMID: 21959408.
Xhajanka E, Hysenaj N, Mulo V, Mele D, Verçani T (2023) The Comparison between the Traditional and Injection Molding Technique in the Construction of Removable Dentures-Systemic Review. Open Access J Dent Oral Surg 5: 1062. DOI : 10.54026/OAJDOS/1062
Published
How to Cite
Issue
Section
Copyright (c) 2023 Prof. Edit Xhajanka, Dr. Neada Hysenaj, Prof. Dr. Vergjini Mulo, Dr. Dorina Mele, Dr. Tedi Verçani, Dr. Endrit Paparisto

This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.